Kia Stinger: Engine Control System / RCV Control Solenoid Valve
Specifications
Item
|
Specification
|
Coil Resistance (Ω)
|
28.3 - 31.1 [20°C(68°F)]
|
Description and operation
Installed on the intercooler inlet pipe, the RCV (Recirculation Valve) Control
Solenoid Valve operates the RCV actuator which controls the by-pass passage of the
turbocharger compressor. When the throttle is closed with the engine running at
cruise rpm (tip-out), the turbocharger boost pressure increases rapidly. The pressure
wave strikes a compressor blades causing a knocking noise. To prevent this, the
ECM opens the recirculation valve which allows excessive boost pressure to vent
back to the air cleaner side of the turbocharger compressor.
Schematic diagrams
Harness Connector
Repair procedures
1. |
Switch "OFF" the ignition.
|
2. |
Disconnect the RCV control solenoid valve connector.
|
3. |
Measure resistance between the valve terminals 1 and 2.
|
4. |
Check that the resistance is within the specification.
Specification : 28.3 - 31.1 Ω [20°C(68°F)]
|
|
1. |
Switch "OFF" the ignition and disconnect the negative (-) battery terminal.
|
2. |
Remove the RCV control solenoid valve after disconnecting the connector
(A), RCV hoses (B).
|
• |
Do not apply oil when hose is assembled.
|
• |
The hose should be inserted perfectly to nipple.
|
|
1. |
Install in the reverse order of removal.
|
Specifications
Specification
Item
Specification
Coil Resistance (Ω)
0.47 - 0.53 [20°C(68°F)]
Description and opera ...
Description and operation
Desrcription
Installed on the turbocharger, the Electric Waste Gate Actuator (EWGA) operates
the vane in the Waste Gate Turbocharger (WGT) and regulates the c ...
Other information:
Specifications
Specification
Temperature
Resistance (kΩ)
°C
°F
-40
-40
40.93 - 48.35
-20
-4
13.89 - 16.03
0
32
...
The driver may choose to only use the cruise control mode (speed control function)
by doing as follows:
1.Turn the smart cruise control system on (the cruise indicator light will be
on but the system will not be activated).
2.Push the distance to distance switch for more than 2 seconds.
3 ...